LK201 C200H PDF

Product category: PLCs – Omron – C – Omron CH-LK (CHLK) This unit is fully tested prior to. Q: Can CH-LKV1 Host Link Unit be used with CS1-series Programmable Controllers?. CH Units that use the CPU bus, SYSMAC LINK Unit, CHW-SLK23/24 ( wired) CHW-SLK13/14 (optical). Controller Link Unit, CHW-CLK21 (wired ).

Author: Tuk Mektilar
Country: Moldova, Republic of
Language: English (Spanish)
Genre: Spiritual
Published (Last): 22 October 2015
Pages: 100
PDF File Size: 2.48 Mb
ePub File Size: 14.27 Mb
ISBN: 113-2-69920-683-4
Downloads: 97688
Price: Free* [*Free Regsitration Required]
Uploader: Mooguzahn

The restriction is strictly mechanical. Can I move the host link to other slot of BB? This is a node address.

Prev 1 2 Next Page 1 of 2. No electrical or logical restriction for using these slots with CH-LK Create an account lk2001 sign in to comment You need to be a member in order to leave a comment Create an account Sign up for a new account in our community. Posted 14 Nov Posted 21 D200h If possible, which cable I have to use? The PLC configuration does not matter. Welcome to the Forum!

As far as using the peripheral port One of the other old school guys will have to answer this one. One says not to use those slots, the other says it’s OK but you will lose some functionality on the peripheral port. Neither of them are V1’s. Posted 14 Nov edited. I just didn’t kk201 the issue when reading the manual. I would still think you should see the RCV light.

  CARTOGRAFIA SENTIMENTAL TRANSFORMAES CONTEMPORNEAS DO DESEJO PDF

If your application is not sending an address and a calculated FCS then it will not communicate with pin 3 set to ON. All the configuration is done with the LK switches.

It determines if addressing is required in the event of a muli-link system. The long port at the bottom is for a 3G2A6-LK You need to be a member in order to leave a comment. Posted 15 Nov edited. Edited 15 Nov by sokhanh. Posted 13 Nov Maybe the backplane is lk21. On the older ones, it was only intended for the hand held programmer. Posted 13 Nov edited.

Posted 20 Nov I did an internet search for your PLC. It is a pre-Alpha series.

I x200h tried with an ch-lkv1 but everything is the same. Started by sokhanh13 Nov The same physical issues occur with high density cards with cables coming out the top. Edited 16 Nov by sokhanh. For communications with CX Programmer, you should be able to use the same cable that is currently connected to you custom application.

Help me with c200h-lk201

By the way, can you tell me the different between lkV1 and lk? Help me with ch-lk Started by sokhanh13 Nov And you put it on the first spot left of the CPU. After revisiting this I found conflicting information in the manuals. You’ll need to tell us in more detail what you have done.

  BLENDI FEVZIU ENVER HOXHA PDF

Omron Ch-lkv1 Host Link Unit | eBay

Posted 22 Nov PCMRthat Data will have to be reentered into the appropriate locations. Try to x200h il elsewhere. What is the part number of your back plane? In any case, look here: You should verify the cable. I also tried with this cable LK Coputer Posted 15 Nov Sign in Already have an account?

Try turning if OFF. I have checked the cable carefullly, the cable should be ok. The 25 pin connector would run into the bottom of those peripheral units if you used these slots.

Omron C200H-LK201 (C200HLK201)

The dip witches in the host link are correct but still c20h connect. Maybe the PLC power supply is bad. It’s on page 9 in the manual.