IEC 287-2-1 PDF

IEC , Electric cables – Calculation of the current rating – Part 2: Thermal resistance – Section 1: Calculation of thermal resistance. IEC Electric cables – Calculation of the current rating – Part 1: Current rating equations (% load factor) and calculation of losses – Section 1: General . IEC Standard (). [4] Electric Cables – Calculation of the current rating – Part 2: Thermal resistance – Section 2A: A method for calculating.

Author: Yozshuktilar Mezill
Country: Iran
Language: English (Spanish)
Genre: Business
Published (Last): 19 February 2015
Pages: 184
PDF File Size: 8.38 Mb
ePub File Size: 4.88 Mb
ISBN: 982-5-58971-521-6
Downloads: 68031
Price: Free* [*Free Regsitration Required]
Uploader: Meztidal

About the author myElectrical Engineering. Thermal resistance — Section 1: We then looked at one method of applying the standard and identified resources enabling the calculation of all the various parameters involved. It is indicated for pipe-type cable indeed, but it is employed for 3 single-core cables also.

IEC Current Capacity of Cables – Rated Current

He has a deep technical understanding of electrical engineering and is keen to share this knowledge. Calculation of the thermal resistance. Download Now Defense manufacturing is all about project manufacturing and project accounting.

This note looks at how to obtain the necessary loss factors for use within You then select an approppropriate protective device to isolated the cable should you exceed this value. Click Here to join Eng-Tips and talk with other members!

  CORRER MARTIN GIACCHETTA PDF

Posting Guidelines Promoting, selling, recruiting, coursework and thesis posting is forbidden. The aim of this paper is to present a parametric study to determine the major factors that influence the calculations of current rating for both air and underground cables.

It can probably be appreciated by now, that in typical real life situations, this can be quite a complicated calculation. Hello, i agree with you that the cables inside the duct are in free air since IEC considers that when calculating T’4 by considering the temprature of the medium filling the duct. The Eng-Tips staff will kec this out and take appropriate action.

Meeting room of the future The IET site has a video of a visit showing of a high tech meeting room developed at Napier University in Edinburgh. When significant, it becomes a factor to be considered in the sizing of cables. In thermal equilibrium, when all these factors have balanced and the temperature of the conductor is the maximum allowable for the insulation; we have the maximum rated current for the cable. It’s easy to join and it’s free.

Have an opinion or something to say, want to ask or answer questions, share your knowledge then use our site to do it. In my opinion it is a conservative value but I accept it.

World Academy of Science, Engineering and Technology

IEC Standard As a community of people interested The standard gives the following equations for the calculation of the cable current rating for all alternating current voltages and direct current up to 5 kV:. Click here to view the notes indexed by tag.

  JOHN WIMBER BOOKS PDF

IEC calculations for three single-core cables in trefoil in 9 way 3 x 3 duct bank 1 First of all it’s our experience for more than 30 years [and of other! Thanks for the feedback. IEC calculations for three single-core cables in trefoil in 9 way 3 x 3 duct bank how is the impact of the mutual heating inside the duct itself is accounted for in your opinion and in this case what is section 2.

IEC 60287 Current Capacity of Cables – Rated Current

You may put in each duct 1, 2, 3 or 4 single core cables. Copyright c ice. Sheath eddy current loss factors for two circuits in flat formation. I appreciate any advice! I 287-22-1 a calculation example here. If you have a load current which is genuinely varying, you could use IEC “Calculation of the cyclic and emergency current rating of cables.

Digital Transformation may be defined in a number of different ways by analysts or enterprise software vendors.